Search results for "Fourier transform ion cyclotron resonance"
showing 10 items of 70 documents
A quartz amplifier for high-sensitivity Fourier-transform ion-cyclotron-resonance measurements with trapped ions
2019
Single-ion sensitivity is obtained in precision Penning-trap experiments devoted to light (anti)particles or ions with low mass-to-charge ratios, by adding an inductance coil to an amplifier connected to the trap, both operated at 4 K. However, single-ion sensitivity has not been reached on heavy singly or doubly charged ions. In this publication, we present a new system to reach this point, based on the use of a quartz crystal as an inductance, together with a newly developed broad-band (BB) amplifier. We detect the reduced-cyclotron frequency of 40Ca+ ions stored in a 7-tesla open-ring Penning trap. By comparing the detected electric signal obtained with the BB amplifier and the fluoresce…
Kinetic instabilities in pulsed operation mode of a 14 GHz electron cyclotron resonance ion source
2016
The occurrence of kinetic plasma instabilities is studied in pulsed operation mode of a 14 GHz Aelectron cyclotron resonance type electron cyclotron resonance ion source. It is shown that the temporal delay between the plasma breakdown and the appearance of the instabilities is on the order of 10- 100 ms. The most important parameters affecting the delay are magnetic field strength and neutral gas pressure. It is demonstrated that kinetic instabilities limit the high charge state ion beam production in the unstable operating regime. peerReviewed
Equipping metallo-supramolecular macrocycles with functional groups: Assemblies of pyridine-substituted urea ligands
2012
A series of di-(m-pyridyl)-urea ligands were prepared and characterized with respect to their conformations by NOESY experiments and crystallography. Methyl substitution in different positions of the pyridine rings provides control over the position of the pyridine N atoms relative to the urea carbonyl group. The ligands were used to self-assemble metallo-supramolecular M(2)L(2) and M(3)L(3) macrocycles which are generated in a finely balanced equilibrium in DMSO and DMF according to DOSY NMR experiments and ESI FTICR mass spectrometry. Again, crystallography was used to characterize the assemblies. Methyl substitution in positions next to the pyridine nitrogen prevents coordination, while …
Characterization of NOM
2015
Worldwide reports over the last few decades have shown that the amount of natural organic matter (NOM) in surface water is continuously increasing, which has an adverse effect on drinking water purification. For many practical and hygienic reasons, the presence of NOM in drinking water is undesirable. Various technologies have been proposed for NOM removal with varying degrees of success. The properties and amount of NOM, however, can significantly affect the process efficiency. To improve and optimize these processes, it is essential to characterize and quantify NOM at various points during purification and treatment. It is also important to be able to understand and predict the reactivity…
Characterization of oligomeric compounds in secondary organic aerosol using liquid chromatography coupled to electrospray ionization Fourier transfor…
2009
The components of secondary organic aerosols (SOAs) generated from the gas-phase ozonolysis of two C(10)H(16)-terpenes (alpha-pinene; sabinene) and a cyclic C(6)H(10) alkene (cyclohexene) were characterized by the use of a Fourier transform ion cyclotron mass spectrometer equipped with an electrospray ionization source operated in the negative ion mode. Reversed-phase high-performance liquid chromatography was used to achieve chromatographic separation of highly oxidized organic compounds. In addition to the well-known group of low molecular weight oxidation products (monomers; e.g. dicarboxylic acids), higher molecular weight compounds (dimers) were also detected and their exact elemental …
Ammonium ion mediated resorcarene capsules: ESI-FTICRMS study on gas-phase structure and ammonium ion affinity of tetraethyl resorcarene and its per-…
2003
AbstractThe ammonium ion binding affinities of tetraethyl resorcarene (1) and its per-methylated derivative (2) were studied by electrospray ionization Fourier transform ion cyclotron resonance (ESI-FTICR) mass spectrometry. Ten different ammonium ions were tested as guests for the resorcarenes. A strong tendency for complex formation was observed with all ammonium ions of size and charge distribution suitable for noncovalent interactions with the cavities of the resorcarene hosts 1 and 2. Although differences in ammonium ion affinities were observed between 1 and 2 due to the dissimilar conformations, the overall tendency was that increase in the degree of substitution and the length of ca…
Rapid determination of pharmaceuticals in wastewater by direct infusion HRMS using target and suspect screening analysis
2021
Abstract A wide-scope screening of active pharmaceutical ingredients (APIs) and their transformation products (TPs) in wastewater can yield valuable insights and pinpoint emerging contaminants that have not been previously reported. Such information is relevant to investigate their occurrence and fate in various environmental compartments. In this study, we explored the applicability of direct infusion high resolution mass spectrometry (DI-HRMS) for comprehensive and rapid detection of APIs and their TPs in wastewater samples. The method was developed using a Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) system and incorporated both wide-scope suspect screening and…
Evaluation of analytical performance of gas chromatography coupled with atmospheric pressure chemical ionization Fourier transform ion cyclotron reso…
2019
Abstract A new analytical method was established and validated for the analysis of eighteen halogenated flame retardants (HFRs)in food products. Gas chromatography (GC) coupled to Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) employing atmospheric pressure chemical ionization (APCI) was used for the identification and quantitation of contaminants. Intra-laboratory validation of the method was performed with respect to recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ), and trueness was verified where possible by analysis of reference materials (RMs). The validation results indicated recoveries of ana…
FT-ICR MS studies of ion-molecule reactions of Ru+ and Os+ with oxygen
2005
Abstract The reactions of stored ruthenium and osmium cations with oxygen have been studied in a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. In case of osmium the reaction products OsO+ and OsO 2 + have been observed and corresponding reaction-rate constants have been determined. In addition, there is an unreactive fraction of Os+ ions due to the presence of a slightly endothermic reacting ground state. Only the excited states react with oxygen. For ruthenium no spontaneous reaction with oxygen has been observed unless the cyclotron motion of Ru+ was excited. The results are discussed with respect to a similar investigation in a Penning trap-TOF mass spectrometer […
The complex formation of tetracyclohexylammonium C1-resorcinarene with various guests - an electrospray ionization Fourier transform ion cyclotron re…
2008
The complex formation of a tetraammonium C1-resorcinarene (R+4HCl) was studied using electrospray ionization Fourier transform ion cyclotron resonance (ESI-FTICR) mass spectrometry. Although R+4HCl easily loses its counter ions in the ESI process, a neutral self-assembled structure with an intramolecular circular hydrogen-bonded 16-membered -N(+)-H ... X(-) ... H-N(+)- array with ammonium ion as the charge-giving species was observed in the gas phase. In addition to chloride, several other counter ions were also studied. The size and basicity of the counter ion as well as the size of the charge-giving cation strongly affected the gas-phase stability of the self-assembled system. H/D exchang…